Next: Heat Generation Rate
Up: Load Definition
Previous: Heat Flux
PROPERTY LOAD CONV [load_name] [loadcase_no] part_name/ALL args
Argument Meaning load_name FEMGEN load name.
loadcase_no FEMGEN loadcase number (links load to an ANSYS step).
part_name Geometry containing element faces/edges.
arg1 Film coefficient value.
arg2 Bulk temperature value.
arg3 Degree of Freedom Indicator (0,1,2).
Notes:
Example FEMGEN Command:
PROPERTY LOAD CONV LO1 1 S1 0.1 100 0
Corresponding ANSYS Input Deck:
SFE, 1,1,CONV,0, 0.1000000 SFE, 1,1,CONV,2, 100.0000 SFE, 2,1,CONV,0, 0.1000000 SFE, 2,1,CONV,2, 100.0000 SFE, 3,1,CONV,0, 0.1000000 SFE, 3,1,CONV,2, 100.0000 SFE, 4,1,CONV,0, 0.1000000 SFE, 4,1,CONV,2, 100.0000
Femsys Limited