next up previous contents
Next: Heat Generation Rate Up: Load Definition Previous: Heat Flux

Convection

PROPERTY LOAD CONV [load_name] [loadcase_no] part_name/ALL args


Argument Meaning
load_name FEMGEN load name.
loadcase_no FEMGEN loadcase number (links load to an ANSYS step).
part_name Geometry containing element faces/edges.
arg1 Film coefficient value.
arg2 Bulk temperature value.
arg3 Degree of Freedom Indicator (0,1,2).
Table 7.13: CONVECTION load arguments.


Notes:

Example FEMGEN Command:

PROPERTY LOAD CONV LO1 1 S1 0.1 100 0

Corresponding ANSYS Input Deck:

      
SFE,       1,1,CONV,0, 0.1000000    
SFE,       1,1,CONV,2,  100.0000    
SFE,       2,1,CONV,0, 0.1000000    
SFE,       2,1,CONV,2,  100.0000    
SFE,       3,1,CONV,0, 0.1000000    
SFE,       3,1,CONV,2,  100.0000    
SFE,       4,1,CONV,0, 0.1000000    
SFE,       4,1,CONV,2,  100.0000


next up previous contents
Next: Heat Generation Rate Up: Load Definition Previous: Heat Flux

Femsys Limited