Next: Convection
Up: Load Definition
Previous: Heat Flow Rate
PROPERTY LOAD HEATFLUX [load_name] [loadcase_no] part_name/ALL args
Argument | Meaning |
load_name | FEMGEN load name. |
loadcase_no | FEMGEN loadcase number (links load to an ANSYS step). |
part_name | Geometry containing element faces/edges. |
arg1 | Heat flux value. |
arg2 | Degree of Freedom Indicator (0,1,2). |
Table 7.12:
HEATFLUX load arguments.
Notes:
- 1.
- Valid part types are beams, plate edges, shell faces, brick faces.
- 2.
- The degree of freedom indicator should be set to zero (normal) for
plate and brick elements. It should be set to 1 or 2 for beams, following
ANSYS convention. For shell elements, if the degree of freedom indicator
is set to zero then the interface program writes it as direction 1 in ANSYS
convention. If it is different from zero, its value (1 or 2) should
follow ANSYS convention.
- 3.
- The user should be warned that, as a result of note 2, when the degree of freedom
indicator is not equal to zero, the load displayed in FEMGEN may not correspond
to its actual definition as seen by ANSYS.
Example FEMGEN Command:
PROPERTY LOAD HEATFLUX LO1 1 S1 1000 0
Corresponding ANSYS Input Deck:
SFE, 1,1,HFLUX,, 1000.000
SFE, 2,1,HFLUX,, 1000.000
SFE, 3,1,HFLUX,, 1000.000
SFE, 4,1,HFLUX,, 1000.000
Next: Convection
Up: Load Definition
Previous: Heat Flow Rate
Femsys Limited
8/18/1999