PROPERTY LOAD HEATFLUX [load_name] [loadcase_no] part_name/ALL args


Argument Meaning
load_name FEMGEN load name.
loadcase_no FEMGEN loadcase number (links load to an ANSYS step).
part_name Geometry containing element faces/edges.
arg1 Heat flux value.
arg2 Degree of Freedom Indicator (0,1,2).
Table 7.12: HEATFLUX load arguments.


Notes:

Example FEMGEN Command:

PROPERTY LOAD HEATFLUX LO1 1 S1 1000 0

Corresponding ANSYS Input Deck:

        
SFE,       1,1,HFLUX,,  1000.000    
SFE,       2,1,HFLUX,,  1000.000    
SFE,       3,1,HFLUX,,  1000.000    
SFE,       4,1,HFLUX,,  1000.000