next up previous contents
Next: Heat Flux Up: Load Definition Previous: Centrifugal Force

Heat Flow Rate

PROPERTY LOAD HEATFLOW [load_name] [loadcase_no] part_name/ALL args


Argument Meaning
load_name FEMGEN load name.
loadcase_no FEMGEN loadcase number (links load to an ANSYS step).
part_name Any geometry containing nodes.
arg1 Heat flow rate value.
Table 7.11: HEATFLOW load arguments.


Notes:

Example FEMGEN Command:

   
PROPERTY LOAD HEATFLOW LO1 1 L1 1000

Corresponding ANSYS Input Deck:

     
F,       1,HEAT,  1000.000    
F,       2,HEAT,  1000.000    
F,       3,HEAT,  1000.000    
F,       4,HEAT,  1000.000    
F,       5,HEAT,  1000.000    
F,       6,HEAT,  1000.000    
F,       7,HEAT,  1000.000    
F,       8,HEAT,  1000.000    
F,       9,HEAT,  1000.000



Femsys Limited
8/18/1999