Next: RESULTS NODAL Attribute [Component] [Complex_part]
Up: Primary Command RESULTS
Previous: RESULTS INVARIANT Attribute [Component] [Complex_part]
This command enables a user to name a specific loadcase, or range of loadcases as the current loadcase(s) from which analysis results will be selected for results presentation.
The loadcase specified remains current until another `RESULTS LOADCASE' command is used to specify a new current loadcase, or until the commands `RESULTS CALCULATE COMBINE' or `RESULTS CALCULATE SCAN' are performed.
Note that when a model is initially selected, the first loadcase for the model is automatically selected as the current loadcase.
Loadcase_name | Range | Comments |
ALL | -- | See note 1. below |
Name | ABOVE min [BELOW max] | See note 1. below |
BELOW max [ABOVE min] | ||
Step [Step] [Step] ... | ||
Step [Step] [Name] ... | ||
Step [TO Step] | ||
Step [TO Name [Step]] | ||
TO Name [Step] | ||
Name [Step] ... | ||
Name [Name] ... |
Notes:
If a range of loadcases is specified then the first loadcase of that range will be used for result presentation modes other than graphing.
The maximum number of loadcases that can be selected is 20000.
Examples:
The loadcase `CASE1' is made current. If `CASE1' has more than one step then the first step is made current except for graphing when all steps are made current.
Step number 5 of loadcase `CREEP' is made current.
All loadcases are made current for graphing. Otherwise the first loadcase found is made current.
All steps of loadcase `FRACT' having step values above 0.5 and below 3.7 are made current for graphing. Otherwise the first valid step found is made current.
The step number 1 of loadcase `THERM' is made current. Steps 1 to 10 of loadcase `THERM' will be used for graphing.
The step number 5 of loadcase `THERM1' is made current. Loadcases from THERM1 step 5 to THERM2 step 10 inclusively will be used for graphing.
The step number 1 of loadcase `THERM' is made current. Steps 1, 2, 5, 6 and 7 will be used for graphing.
The loadcase `CASE1' or its first step is made current. All of CASE1 and CASE2, step 1 and 2 of CASE3, and CASE4 will be used for graphing.
See also the following commands
Femsys Limited