Next: PROPERTY BOUNDARY RELEASE [name] part dof
Up: PROPERTY BOUNDARY
Previous: PROPERTY BOUNDARY MPC EQUA none
This command is used to prescribe a value to a degree of freedom for a particular loadcase (the default is all loadcases). The command has the same effect as the PROPERTY LOAD DISPLACE command but is much more general in that any degree of freedom may be referenced. The degree of freedom names listed below are the defaults; these may be changed via the FEMGV resource file (see the Installation and Customisation Guide).
name | = | constraint name for use in future references. |
part | = | the name of a point, line, surface, body, or set. |
dof | = | prescribed degree of freedom. |
1 or X | = | x-translation |
2 or Y | = | y-translation |
3 or Z | = | z-translation |
4 or RX | = | x-rotation |
5 or RY | = | y-rotation |
6 or RZ | = | z-rotation |
7 or W | = | beam warping |
8 or P | = | pore pressure |
10 or E | = | electrical potential |
11 or T | = | temperature |
value | = | the value to be assigned to dof |
lcas | = | optional loadcase number |
Notes:
Examples:
Set the temperature of all nodes on S1 to 273.
See also the following commands
'LABEL GEOMETRY CONSTRNT'
'LABEL MESH CONSTRNT'
'LABEL OPTIONS CONSTRNT'
'UTILITY DELETE CONSTRNT'
'UTILITY TABULATE PROPERTY CONSTRNT'
Femsys Limited