This command is used to define the work-box space and its use.
Control | | Comments |
CHECKING | OFF | Sets the severity level of coordinate checking |
| WARN | against the work-box (see note 1). |
| ERROR | |
SIZE | AUTOMATIC | Sets mode of operation and the size of the |
| SET | work-box (see note 2). |
| Coords | |
Coords | | Sets the size of the work-box (see note 3). |
Notes:
- 1.
- Coordinate checking
The coordinates of defined or generated points may be checked against the
work-box.
If CONSTRUCT SPACE WORK-BOX CHECKING WARN is selected then points defined or
generated having coordinates
outside the work-box will cause a warning message to be generated. This is the
default. If ...... WORK-BOX CHECKING ERROR
is selected then points defined or generated having coordinates
outside the work-box will cause an error condition and the
points will not be created. Coordinate checking is switched off entirely with
the ...... WORK-BOX CHECKING OFF command.
- 2.
- Mode of operation
If coordinate checking against the workbox is switched
to WARN or OFF then the CONSTRUCT SPACE WORK-BOX SIZE AUTOMATIC
command will cause the work-box to be sized
automatically after the generation of each new point. This is the
default mode of operation. The work-box
can then be fixed at its current size by the CONSTRUCT SPACE WORK-BOX SIZE SET
command.
- 3.
- Setting the work-box size
The size of the work-box can be set by giving the
coordinates for the corner of the box having maximum values
for x, y, and z; optionally followed by the coordinates of
the corner having minimum values for x, y, and z. If only one value is given
this is used as the maximum for all three directions. If minimum
values are not specified they are taken as = 0. The dimensions of the work box may be
changed at any time during the definition of a model.
The diagonal of the work-box may be used to set the tolerance for checking point
coincidence with the CONSTRUCT SPACE TOLERANCE RELATIVE command.
The work-box may be displayed using the command EYE LOCATE within FEMGEN .
Examples:
- 1.
- CONSTRUCT SPACE WORK-BOX 12
Constructs a work-box of [0,0,0] to [12,12,12]
- 2.
- CONSTRUCT SPACE WORK-BOX 5 5 7 -3 1 0
Constructs a work-box of [-3 1 0] to [5 5 7]
- 3.
- CONSTRUCT SPACE WORK-BOX SET
The work-box is fixed at its current size.
See also the following commands