DI211
|
DI??? : INVALID TEMPORARY FILE UNIT NUMBER (IUNT) : (UNIT No.)
|
This channel number was not specified as one that would be used
in a previous call to routine DIINI.
|
DI212
|
DICOR : NODE IDENTIFICATION NUMBERS NOT IN ASCENDING ORDER :
(IDNNUM)
|
See notes on DICOR
|
DI213
|
DI??? : NODE IDENTIFICATION NUMBERS CANNOT BE LESS THAN 1 :
(IDNNUM)
|
See 'Restrictions' section in chapter 1.
|
DI215
|
DI??? : NODE ID > 99999 NOT ALLOWED FOR 5 DIGIT TEXT
FILE
|
: (IDNNUM )
|
|
See 'Restrictions' section in chapter 1.
|
DI216
|
DI??? : ERROR IN WRITING TO TEMPORARY FILE ON UNIT (IUNT)
|
: (UNIT No.)
|
|
This channel number was not specified as one that would be used
in a previouscall to routine DIINI.
|
DI217
|
DITOP : ELEMENT ID NUMBERS CANNOT BE LESS THAN 1
|
|
: (IDENUM )
|
See 'Restrictions' section in chapter 1.
|
DI218
|
DITOP : INVALID FEMVIEW ELEMENT TYPE NUMBER (ITYPE) : (ITYPE
)
|
Parameter ITYPE must be in the range 1 to 16. See FEMGV User
Manual Appendix B.
|
DI221
|
DITOP : ELMT ID > 99999 NOT
ALLOWED FOR 5 DIGIT TEXT FILE: (IDENUM )
|
See 'Restrictions' section in chapter 1.
|
DI222
|
DISIZ : MODEL IS TOO LARGE FOR FEMVIEW (MSIZE)
|
: (MSIZE )
|
|
This error is no longer produced.
|
DI223
|
DIBLD : ERROR BUILDING FEMVIEW DISPLAY DATA SETS
|
: (STAGE No.)
|
|
Elements entered in previous call to DITOP reference non-existent
nodes, or no outline edges in model.
|
DI224
|
DI??? : ERROR IN WRITING TO TEMPORARY FILE ON UNIT (IUNT)
|
: (UNIT No.)
|
|
This channel number was not specified as one that would
be used in a previous call
|
|
|
to routine DIINI.
|
DI225
|
DI??? : ERROR IN READING TEMPORARY FILE ON UNIT (IUNT)
|
: (UNIT No.)
|
|
This channel number was not specified as one that would
be used in a previous call
|
|
|
to routine DIINI.
|
DI226
|
DILIM : ASSEMBLY COMPONENT NOT FOUND
|
: (NAME )
|
|
Assembly components must already have been entered into the FEMVIEW
database.
|
DI227
|
DILIM : INCOMPLETE MODEL DATA IN ASSEMBLY SUB-COMPONENT
|
: (NAME )
|
|
Routine DIBLD has not been called for one of the assembly sub-components.
|
DI228
|
DILIM : TRANSFORM FOR
ASSEMBLY COMPONENT NOT FOUND
|
|
|
Assembly definition references an unknown transformation identification
number for a previously entered model or sub-assembly.
|
DI229
|
DILIM : SET INDEX IS CORRUPT
|
|
DI231
|
DILIM : NAMED SET ALREADY EXISTS : (STNAME )
|
Cannot append element set information to an existing element
set.
|
DI232
|
DILIM : TOO MANY ELEMENTS IN SET
|
The FEMVIEW 5 database page size is insufficient for the number
of elements in the set. Contact your FEMVIEW distributor.
|
DI233
|
DILIM : ELEMENTS IN SET NOT IN SAME ORDER AS IN TOPOLOGY
|
:
|
|
Element identification numbers entered as part of an element
set must be in the same numerical order as the element identification numbers
entered in the element topology dataset.
|
DI234
|
DILIM : TOO MANY TRANSFORMATIONS
|
A maximum of 100 transformations are allowed for any one model.
|
DI235
|
DILIM : ATTRIBUTE NAME ALREADY USED IN THIS LOADCASE :
(ANAME )
|
All attribute names within a single loadcase must be different.
|
DI236
|
DILIM : ERROR IN NODAL RESULTS HEADER RECORD
|
This should be trapped out by a previous routine.
|
DI237
|
DILIM : ERROR IN NODAL RESULTS
|
This should be trapped out by a previous routine.
|
DI238
|
DI??? : NODE DOES NOT EXIST
|
: (NODE No.)
|
|
Nodal results header refers to a non-existent node identification
number.
|
DI239
|
DILIM : ELEMENT DOES NOT EXIST : (EL NO.)
|
Element results header refers to a non-existent node identification
number.
|
DI241
|
DILIM : ERROR IN READING ELEMENT RESULTS
|
This should be trapped out by a previous routine.
|
DI242
|
DILIM : ERROR IN READING GAUSS POINT COORDINATES
|
This should be trapped out by a previous routine.
|
DI243
|
DILIM : ERROR IN ELEMENT RESULTS DATA
|
This should be trapped out by a previous routine.
|
DI244
|
DILIM : LOADCASE COMBINATION ALREADY DEFINED
|
Combined loadcases must not use loadcase names which already
exist for the current model.
|
DI245
|
DILIM : NO LOAD CASES IN COMBINATIONS
|
This should be trapped out by a previous routine.
|
DI246
|
DILIM : ERROR IN READING BEAM LOAD HEADER
|
|
|
This should be trapped out by a previous routine.
|
DI247
|
DILIM : ERROR IN READING BEAM LOAD DATA
|
|
|
This should be trapped out by a previous routine
|
DI248
|
DILIM : ILLEGAL FEMVIEW CALCULATION NAME
|
: (NCALC )
|
|
This should be trapped out by a previous routine.
|
DI249
|
DILIM : NO VALID NODAL RESULTS FOUND FOR THIS DATASET
|
All of the nodes referenced by this set of results were non-existent.
See warning/information messages in next section.
|
DI251
|
DILIM : NO VALID ELEMENT RESULTS FOUND FOR THIS DATASET
|
|
|
All of the elements referenced by this set of results were non-existent.
See warning/information messages in next section.
|
DI253
|
DI??? : SYSTEM ID NUMBERS CANNOT BE LESS THAN 0
|
: (IDSNUM )
|
|
See 'Restrictions' section in chapter 1
|
DI254
|
DI??? : SYSTEM ID NUMBERS ABOVE 999999 INVALID
|
|
: (IDSNUM )
|
See 'Restrictions' section in chapter 1
|
DI255
|
DI??? : SYSTEM ID ABOVE 99999 INVALID FOR CHARACTER FILE
|
: (IDSNUM )
|
|
See 'Restrictions' section in chapter 1
|
DI256
|
DITOP2 : LESS THAN ZERO FEMGEN ELEMENT VARIANT (IELVAR)
: (IELVAR )
|
See 'Restrictions' section in chapter 1
|
DI257
|
DILIM : NO VALID LOCAL SYSTEMS FOUND FOR THIS DATASET
|
|
|
A local system dataset has been created with no valid systems.
|
DI258
|
DILIM : NO VALID MPC DEFINITIONS FOUND FOR THIS DATASET
|
|
|
An MPC dataset has been created with no valid MPCs. It is likely
that DIMPD has been used to enter slave and master nodes which do not actually
exist in the model geometry.
|
DI259
|
DILIM : NO VALID GAUSS COORDINATES FOUND FOR THIS DATASET
|
A Gauss points dataset has been created with no valid Gauss points.
|
DI261
|
DILIM : NODES IN SET MUST BE IN ASCENDING ORDER
|
|
DI262
|
DILIM : RESULTS RECORD TOO LARGE FOR DATABASE PAGE
|
|
|
|
DI263
|
DILIM : LOADCASE SCAN ALREADY DEFINED
|
|
|
Scan loadcases must not use loadcase names which already exist
for the current model.
|
DI264
|
DILIM : NO LOADCASES FOR SCAN
|
This should be trapped out by a previous routine.
|
DI299
|
DI??? : *** PREVIOUS ERROR NOT SUCCESSFULLY DETECTED ***
|
: (MORE INF)
|
|
This error should never occur. If this error does occur, it means
that one or more of the error checks in the callable Database Interface Routines
is not working correctly. This indicates a possible programming error within
the Database Interface Routines and should be reported to FEMSYS Ltd.
|