[Next] [Up] [Back] [Previous] [Contents]

3.3 Error Messages Requiring Current Model To Be Abandoned

DI211 DI??? : INVALID TEMPORARY FILE UNIT NUMBER (IUNT) : (UNIT No.)

This channel number was not specified as one that would be used in a previous call to routine DIINI.
DI212 DICOR : NODE IDENTIFICATION NUMBERS NOT IN ASCENDING ORDER : (IDNNUM) See notes on DICOR
DI213 DI??? : NODE IDENTIFICATION NUMBERS CANNOT BE LESS THAN 1 : (IDNNUM) See 'Restrictions' section in chapter 1.

DI215
DI??? : NODE ID > 99999 NOT ALLOWED FOR 5 DIGIT TEXT FILE : (IDNNUM )
See 'Restrictions' section in chapter 1.

DI216
DI??? : ERROR IN WRITING TO TEMPORARY FILE ON UNIT (IUNT) : (UNIT No.)

This channel number was not specified as one that would be used in a previouscall to routine DIINI.
DI217
DITOP : ELEMENT ID NUMBERS CANNOT BE LESS THAN 1  
: (IDENUM )
See 'Restrictions' section in chapter 1.
DI218 DITOP : INVALID FEMVIEW ELEMENT TYPE NUMBER (ITYPE) : (ITYPE ) Parameter ITYPE must be in the range 1 to 16. See FEMGV User Manual Appendix B.
DI221 DITOP : ELMT ID > 99999 NOT
ALLOWED FOR 5 DIGIT TEXT FILE: (IDENUM )
See 'Restrictions' section in chapter 1.
DI222
DISIZ : MODEL IS TOO LARGE FOR FEMVIEW (MSIZE) : (MSIZE )
This error is no longer produced.
DI223
DIBLD : ERROR BUILDING FEMVIEW DISPLAY DATA SETS : (STAGE No.)
Elements entered in previous call to DITOP reference non-existent nodes, or no outline edges in model.
DI224
DI??? : ERROR IN WRITING TO TEMPORARY FILE ON UNIT (IUNT) : (UNIT No.)
This channel number was not specified as one that would be used in a previous call    
to routine DIINI.
DI225
DI??? : ERROR IN READING TEMPORARY FILE ON UNIT (IUNT) : (UNIT No.)
This channel number was not specified as one that would be used in a previous call    
to routine DIINI.
DI226
DILIM : ASSEMBLY COMPONENT NOT FOUND : (NAME )
Assembly components must already have been entered into the FEMVIEW database.
DI227
DILIM : INCOMPLETE MODEL DATA IN ASSEMBLY SUB-COMPONENT : (NAME )
Routine DIBLD has not been called for one of the assembly sub-components.
DI228
DILIM : TRANSFORM FOR ASSEMBLY COMPONENT NOT FOUND  
 
Assembly definition references an unknown transformation identification number for a previously entered model or sub-assembly.


DI229 DILIM : SET INDEX IS CORRUPT  
DI231 DILIM : NAMED SET ALREADY EXISTS : (STNAME ) Cannot append element set information to an existing element set.
DI232 DILIM : TOO MANY ELEMENTS IN SET The FEMVIEW 5 database page size is insufficient for the number of elements in the set. Contact your FEMVIEW distributor.
DI233
DILIM : ELEMENTS IN SET NOT IN SAME ORDER AS IN TOPOLOGY :



Element identification numbers entered as part of an element set must be in the same numerical order as the element identification numbers entered in the element topology dataset.
DI234 DILIM : TOO MANY TRANSFORMATIONS A maximum of 100 transformations are allowed for any one model.
DI235 DILIM : ATTRIBUTE NAME ALREADY USED IN THIS LOADCASE : (ANAME ) All attribute names within a single loadcase must be different.
DI236 DILIM : ERROR IN NODAL RESULTS HEADER RECORD This should be trapped out by a previous routine.
DI237 DILIM : ERROR IN NODAL RESULTS This should be trapped out by a previous routine.
DI238
DI??? : NODE DOES NOT EXIST : (NODE No.)
Nodal results header refers to a non-existent node identification number.
DI239 DILIM : ELEMENT DOES NOT EXIST : (EL NO.) Element results header refers to a non-existent node identification number.
DI241 DILIM : ERROR IN READING ELEMENT RESULTS This should be trapped out by a previous routine.
DI242 DILIM : ERROR IN READING GAUSS POINT COORDINATES This should be trapped out by a previous routine.
DI243 DILIM : ERROR IN ELEMENT RESULTS DATA This should be trapped out by a previous routine.
DI244 DILIM : LOADCASE COMBINATION ALREADY DEFINED Combined loadcases must not use loadcase names which already exist for the current model.
DI245 DILIM : NO LOAD CASES IN COMBINATIONS This should be trapped out by a previous routine.
DI246

DILIM : ERROR IN READING BEAM LOAD HEADER  
 
This should be trapped out by a previous routine.
DI247
DILIM : ERROR IN READING BEAM LOAD DATA  
 
This should be trapped out by a previous routine
DI248
DILIM : ILLEGAL FEMVIEW CALCULATION NAME : (NCALC )
This should be trapped out by a previous routine.




DI249 DILIM : NO VALID NODAL RESULTS FOUND FOR THIS DATASET All of the nodes referenced by this set of results were non-existent. See warning/information messages in next section.
DI251
DILIM : NO VALID ELEMENT RESULTS FOUND FOR THIS DATASET  
 
All of the elements referenced by this set of results were non-existent. See warning/information messages in next section.
DI253
DI??? : SYSTEM ID NUMBERS CANNOT BE LESS THAN 0 : (IDSNUM )
See 'Restrictions' section in chapter 1
DI254
DI??? : SYSTEM ID NUMBERS ABOVE 999999 INVALID  
: (IDSNUM )
See 'Restrictions' section in chapter 1
DI255
DI??? : SYSTEM ID ABOVE 99999 INVALID FOR CHARACTER FILE : (IDSNUM )
See 'Restrictions' section in chapter 1
DI256 DITOP2 : LESS THAN ZERO FEMGEN ELEMENT VARIANT (IELVAR)
: (IELVAR )
See 'Restrictions' section in chapter 1
DI257
DILIM : NO VALID LOCAL SYSTEMS FOUND FOR THIS DATASET  
 
A local system dataset has been created with no valid systems.

DI258
DILIM : NO VALID MPC DEFINITIONS FOUND FOR THIS DATASET  
 
An MPC dataset has been created with no valid MPCs. It is likely that DIMPD has been used to enter slave and master nodes which do not actually exist in the model geometry.
DI259 DILIM : NO VALID GAUSS COORDINATES FOUND FOR THIS DATASET A Gauss points dataset has been created with no valid Gauss points.
DI261 DILIM : NODES IN SET MUST BE IN ASCENDING ORDER  
DI262
DILIM : RESULTS RECORD TOO LARGE FOR DATABASE PAGE  
 
 
DI263
DILIM : LOADCASE SCAN ALREADY DEFINED  
 
Scan loadcases must not use loadcase names which already exist for the current model.
DI264 DILIM : NO LOADCASES FOR SCAN This should be trapped out by a previous routine.
DI299
DI??? : *** PREVIOUS ERROR NOT SUCCESSFULLY DETECTED *** : (MORE INF)
This error should never occur. If this error does occur, it means that one or more of the error checks in the callable Database Interface Routines is not working correctly. This indicates a possible programming error within the Database Interface Routines and should be reported to FEMSYS Ltd.

   



[Next] [Up] [Back] [Previous] [Contents]