[Next] [Up] [Back] [Previous] [Contents]

3.2 Error Messages Requiring Current Dataset To Be Abandoned

Error Number Error Message Description
DI111 DI??? : A MODEL DATASET IS STILL ACTIVE ON UNIT (IUNT) : (UNIT No.) Either a dataset is truly incomplete, or routine DILIM has not been called to process the information. When parallel processing the unit numbers may be at fault.
DI112
DIHED : INVALID DATASET HEADER KEY : (KEY )
Parameter KEY is incorrect, refer to Appendix 1
DI113
DIHED : INVALID OPCODE  
: (OPCODE )
Parameter OPCODE must be 1, 2, or 3.
DI114
DIHED : CANNOT ENTER NODAL COORDINATES, NO MODEL ACTIVE  
 
A previous call to DIHED to enter a model name has probably failed
DI115 DIHED : CANNOT APPEND NODAL COORDINATES See flow chart.
DI116

DIHED : CANNOT ENTER NODAL COORDINATES AT ASSEMBLY LEVEL  
 
See flow chart.
DI117 DIHED : NODAL COORDINATES ALREADY ENTERED FOR THIS MODEL See flow chart.
DI118
DIHED : FOR KEYS OTHER THAN 1, OPCODE MUST BE 1 (CREATE)  
 
See Appendix 1.

DI119
DIHED : CANNOT ENTER ELEMENT TOPOLOGY, NO MODEL ACTIVE  
 
A previous call to DIHED to enter a model name has probably failed.
DI121 DIHED : CANNOT APPEND ELEMENT TOPOLOGY  
DI122 DIHED : CANNOT ENTER ELEMENT TOPOLOGY AT ASSEMBLY LEVEL See flow chart.


DI123

DIHED : ELEMENT TOPOLOGY ALREADY ENTERED FOR THIS MODEL See flow chart.

DI124
DIHED : CANNOT ENTER ELEMENT SETS AT THE ASSEMBLY LEVEL  
 
See notes with flow chart.  

 
DI125
DIHED : CANNOT ENTER MATERIALS AT THE ASSEMBLY LEVEL  
 
See notes with flow chart.
DI126 DIHED : NODAL COORDINATES MUST BE ENTERED BEFORE RESULTS See flow chart.
DI127 DIHED : ELEMENT TOPOLOGY MUST BE ENTERED BEFORE RESULTS See flow chart.


DI128 DIHED : LOADCASE NAME MUST BE NON-BLANK  
DI129 DI??? : ERROR IN WRITING TO TEMPORARY FILE ON UNIT (IUNT)
: (UNIT No.)
Check that the temporary file has been opened correctly and when parallel processing that the correct unit number is being used.
DI131 DICOR : CANNOT ENTER NODAL COORDINATES, CURRENT DATASET IS : (KEY) The value of KEY set in a previous call to DIHED is inconsistent with this data set.
Refer to Appendix 1.
DI132 DITOP : CANNOT ENTER ELEMENT TOPOLOGY, CURRENT DATASET IS : (KEY) The value of KEY set in a previous call to DIHED is inconsistent with this dataset. Refer to Appendix 1.
DI133
DISET : CANNOT ENTER ELEMENT SET, CURRENT DATASET IS : (KEY)
The value of KEY set in a previous call to DIHED is inconsistent with this data set.
Refer to Appendix 1.
DI134 DISET : SET NAME MUST BE NON-BLANK  
DI135
DIASS : CURRENT MODEL TYPE IS NOT ASSEMBLY  
 
The value of OPCODE set in a previous call to DIHED is inconsistent with this dataset.
Refer to Appendix 1.
DI136 DIASS : INVALID NUMBER OF TRANSFORMATION MATRICES (NUMTRA) : (NUMTRA Parameter NUMTRA must be in the range 0 to 12 for assembly sub-components.
DI137

DIASS : MODEL/SUB-ASSEMBLY MUST ALREADY EXIST (NAME) : (NAME )
An assembly is built up from a collection of models/sub-assemblies with optional transformations, which have already been entered into the FEMVIEW database. The requested model/sub-assembly does not exist in the database
DI138
DI??? : CANNOT ENTER LOAD COMB/SCAN, CURRENT DATASET IS : (KEY)
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1.
DI139
DITRN : CANNOT ENTER TRANSFORMATION, CURRENT DATASET IS : (KEY )
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1.
DI141
DI??? : ID NUMBERS CANNOT BE LESS THAN 1 : (IDNUM )
See 'Restrictions' section in chapter 1.
DI142
DI??? : ID NUMBERS ABOVE 999999 ARE INVALID : (IDNUM)
See 'Restrictions' section in chapter 1.
DI143 DI??? : ID ABOVE 99999 NOT ALLOWED FOR 5 DIGIT TEXT FILE
: (IDNUM)
See 'Restrictions' section in chapter 1.


DI144
DIBLH : CANNOT ENTER BEAM LOAD, CURRENT DATASET IS : (KEY)
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1.
DI145 DIBLH : BEAM LOAD DATA FOR LAST BEAM NOT COMPLETED A previous call to DIBLH indicated a certain number of loads of each type for this beam element. Routines DIBL1 to DIBL4 have not been called often enough, and more load data is expected.








DI146 DIBL? : BEAM LOAD HEADER EXPECTED A previous call to DIBLH indicated a certain number of loads of each type for this beam element. Routines DIBL1 to DIBL4 have been called too many times, and no more load data is expected.
DI147
DIBL? : NONE INDICATED OR ALREADY DONE FOR CURRENT BEAM  
 
A previous call to DIBLH indicated a certain number of loads of each type for this beam element. One of the routines DIBL1 to DIBL4 has been called too many times.
DI148
DIBL2 : POINT LOADS MUST PRECEDE DISTRIBUTED LOADS :

Beam loading data types must be entered in the following order: point loads, distributed loads, point bending moments, distributed bending moments.
DI149 DIBL3 : DISTRIBUTED LOADS MUST PRECEDE POINT MOMENTS Beam loading data types must be entered in the following order: point loads, distributed loads, point bending moments, distributed bending moments.
DI151
DIBL4 : POINT MOMENTS MUST PRECEDE DISTRIBUTED MOMENTS  
 
Beam loading data types must be entered in the following order: point loads, distributed loads, point bending moments, distributed bending moments.
DI152
DIMT? : CANNOT ENTER MATERIALS, CURRENT DATASET IS : (KEY )
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1.
DI153 DICON : CONSTRAINTS NOT ENTERED IN ASCENDING NODE ORDER  
DI154
DIMPH : ITYPE MUST BE IN THE RANGE 1-14 (ITYPE) : (ITYPE )
 
DI155 DIMPH : INVALID NUMBER(S) OF MPC NODES Either MASTER or NSLAVE is not in the range 0-99999.
DI156
DIRHA : CANNOT ENTER RESULTS, CURRENT DATASET IS : (KEY )
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1.
DI157

DIRHA : ATTRIBUTE HEADER ALREADY    
 
Routine DIRHA is called only once for each user-defined results dataset.
DI158
DIE?H : MORE REPEATS EXPECTED FOR PREVIOUS ELEMENT  
 
The number of repeats specified in a previous call to DIE?H has not been followed by enough calls to DIE?R. See flow chart.
DI159
DIE?R : NO MORE REPEATS EXPECTED FOR THIS ELEMENT  
 
The number of repeats specified in a previous call to DIE?H has been followed by too many calls to DIE?R. See flow chart.
DI161 DIRHB : ATTRIBUTE HEADER EXPECTED Routine DIRHA must be called before routine DIRHB. See flow chart.

DI162 DIRHB : NO MORE COMPONENT DEFINITIONS EXPECTED The number of components specified in a previous call to DIRHA is inconsistent with the number of components that are now being entered via DIRHB.
DI163 DIRHC : COMPONENT DEFINITIONS NOT COMPLETED The number of components specified in a previous call to DIRHA has not been with the number of components that are now being entered via DIRHC.
DI164 DIRHC : NO MORE ATTRIBUTE VARIANTS EXPECTED The number of attribute variants specified in a previous call to DIRHA is inconsistent with the number of attribute variants that are now being entered via DIRHC.
DI165 DI??? : RESULTS HEADERS HAVE NOT BEEN COMPLETED Routines DIRHA, DIRHB, and DIRHC have not been called correctly prior to entering a user-defined results dataset.
DI166 DI??? : CANNOT ENTER RESULTS, CURRENT RESULTS TYPE IS: (IRTYPE ) The value of IRTYPE set in a previous call to DIRHA is inconsistent with this results data set type. Refer to Appendix 1.
DI167
DI??? : THIS NUMBER OF COMPONENTS NOT EXPECTED (NUMRES) : (NUMRES )
The number of components specified in a previous call to DIRHA has been followed by an inconsistent number of calls to DI??R. See flow chart.
DI168
DIMPH : TOO MANY NODES IN MPC DEFINITION (NTOTAL) : (NTOTAL)
NTOTAL = NSLAVE + NMASTR and it must not exceed 30.
DI169 DI??? : ID NUMBERS NOT IN ASCENDING ORDER Many nodal datasets require the data to be entered in ascending ID number.


DI171
DIRHB : INVALID LENGTH FOR CURRENT ENUMERATIVE LIST : (IEXIST)
The maximum length is five.
DI172
DINDH : MORE REPEATS EXPECTED FOR PREVIOUS NODE  
 
The number of repeats specified in a previous call to DINDH has been followed by too few calls to DINDR. See flow chart.
DI173 DINDR : NO MORE REPEATS EXPECTED FOR THIS NODE The number of repeats specified in a previous call to DINDH has been followed by too many calls to DINDR. See flow chart.










DI174

DIMPH : MORE REPEATS EXPECTED FOR PREVIOUS MPC  
 
A previous call to DIMPH indicated that DIMPD should be called a certain number of times. DIMPH has been called for the next MPC without finishing entering data from the last one.
DI175 DIMPD : NO MORE REPEATS EXPECTED FOR THIS MPC A previous call to DIMPH indicated that DIMPD should be called a certain number of times. DIMPD has been called too often.
DI176 DICON : IDOF AND IEDOF CANNOT BOTH BE ZERO  
DI177
DI??? : INVALID LOCAL AXIS SYSTEM INDICATOR : (IDSNUM )
See 'Restrictions' section in chapter 1.
DI178 DIMPD : PARAMETER NNODES MUST BE ZERO FOR MPC TYPE > 11: (NNODES )  
DI179 DIMPD : INCONSISTENT NUMBER OF MPC NODES FOR MPC <= 11: (NNODES )  
DI181
DILIM : CANNOT PROCESS INCOMPLETE DATASET ON UNIT (IUNT) : (UNIT No.)
Routine DILIM has probably been called when more results or data were expected from one of the datasets. When parallel processing, check that you are trying to process the correct dataset.
DI182
DIRHA : INVALID RESULTS TYPE (IRTYPE) : (IRTYPE )
Parameter IRTYPE must be in the range 1 to 5.
DI183
DIRHA : INVALID NUMBER OF COMPONENTS (NCOMPS) : (NCOMPS )
Parameter NCOMPS must be in the range 1 to 20.


DI184
DIRHA : INVALID NUMBER OF ATTRIBUTE VARIANTS (NUMVAR) : (NUMVAR )
Parameter NUMVAR must be in the range 0 to 5.
DI185
DIRHB : INVALID MENU INCLUSION INDICATOR (INMENU) : (INMENU )
Parameter INMENU must be 1 or 0.
DI186
DIRHB : INVALID COMPONENT TYPE (CTYPE : (CTYPE )
Parameter CTYPE must be 1,2,3,4,5,11,12,13, or 14.
DI187
DIRHB : INVALID SUB-COMPONENT INDEX (INDEX1) : (INDEX1 )
Value of INDEX1 is inconsistent with parameter CTYPE.
DI188 DIRHB : INVALID MATRIX COLUMN (INDEX2) Value of INDEX1 is inconsistent with parameter CTYPE.
DI189
DIRHB : INVALID CALCULATION INDICATOR (IEXIST) : (IEXIST )
Parameter IEXIST must be 1 or 0.

DI191
DIRHB : INVALID FEMVIEW CALCULATION TYPE NAME (NCALC) : (NCALC )
See Appendix two for a list of valid FEMVIEW post calculation types.
DI192
DIRHC : TOO MANY COMPONENTS IN ATTRIBUTE VARIANT  
 
Parameter NVCOMP must be in the range 1 to 20

DI193 DIHED : CANNOT ENTER RESULTS, NO MODEL ACTIVE A previous call to DIHED to enter a model name has probably failed.

DI194
DI??? : CANNOT ENTER THIS DATA TYPE, CURRENT DATASET IS : (KEY )
A previous call to DIHED indicated that a certain dataset was to follow and it was not the one you are trying to use now. When parallel processing check the unit numbers.
DI195 DICON : CANNOT ENTER NODAL CONSTRAINTS, CURRENT DATASET IS
: (KEY )
A previous call to DIHED indicated that a certain dataset was to follow and it was not nodal constraints. When parallel processing check the unit numbers.
DI196 DICON : INVALID NODAL CONSTRAINT DEFINITION (IDOF)
: (IDOF )
IDOF does not obey the rules defined for DICON.

DI197 DICON : INVALID NODAL CONSTRAINT DEFINITION (IEDOF): (IEDOF ) IEDOF does not obey the rules defined for DICON.
DI198
DI??? : CANNOT ENTER DATA, ENTITY HEADER NOT ENTERED  
 
For datasets with header records an attempt has been made to enter data via DI??D or DI??R without first making a call to DI??H.
DI199
DINDR : MATERIAL ID NUMBERS CANNOT BE LESS THAN ZERO : (IDMNUM )
Note that material ID numbers equal to zero may be used for multi-surface material independent data, but in general zero ID numbers for other data are invalid.

   


[Next] [Up] [Back] [Previous] [Contents]