Error Number | Error Message | Description | ||||
DI111 | DI??? : A MODEL DATASET IS STILL ACTIVE ON UNIT (IUNT) : (UNIT No.) | Either a dataset is truly incomplete, or routine DILIM has not been called to process the information. When parallel processing the unit numbers may be at fault. | ||||
DI112 |
|
Parameter KEY is incorrect, refer to Appendix 1 | ||||
DI113 |
|
Parameter OPCODE must be 1, 2, or 3. | ||||
DI114 |
|
A previous call to DIHED to enter a model name has probably failed | ||||
DI115 | DIHED : CANNOT APPEND NODAL COORDINATES | See flow chart. | ||||
DI116
|
|
See flow chart. | ||||
DI117 | DIHED : NODAL COORDINATES ALREADY ENTERED FOR THIS MODEL | See flow chart. | ||||
DI118 |
|
See Appendix 1. |
||||
DI119 |
|
A previous call to DIHED to enter a model name has probably failed. | ||||
DI121 | DIHED : CANNOT APPEND ELEMENT TOPOLOGY | |||||
DI122 | DIHED : CANNOT ENTER ELEMENT TOPOLOGY AT ASSEMBLY LEVEL |
See flow chart. |
||||
DI123 |
DIHED : ELEMENT TOPOLOGY ALREADY ENTERED FOR THIS MODEL |
See flow chart. |
||||
DI124 |
|
|
||||
DI125 |
|
See notes with flow chart. | ||||
DI126 | DIHED : NODAL COORDINATES MUST BE ENTERED BEFORE RESULTS | See flow chart. | ||||
DI127 | DIHED : ELEMENT TOPOLOGY MUST BE ENTERED BEFORE RESULTS | See flow chart. |
DI128 | DIHED : LOADCASE NAME MUST BE NON-BLANK | |||
DI129 |
DI??? : ERROR IN WRITING TO TEMPORARY FILE ON UNIT (IUNT) : (UNIT No.) |
Check that the temporary file has been opened correctly and when parallel processing that the correct unit number is being used. | ||
DI131 | DICOR : CANNOT ENTER NODAL COORDINATES, CURRENT DATASET IS : (KEY) |
The value of KEY set in a previous call to DIHED is inconsistent
with this data set. Refer to Appendix 1. |
||
DI132 | DITOP : CANNOT ENTER ELEMENT TOPOLOGY, CURRENT DATASET IS : (KEY) | The value of KEY set in a previous call to DIHED is inconsistent with this dataset. Refer to Appendix 1. | ||
DI133 |
|
The value of KEY set in a previous call to DIHED is inconsistent
with this data set. Refer to Appendix 1. |
||
DI134 | DISET : SET NAME MUST BE NON-BLANK | |||
DI135 |
|
The value of OPCODE set in a previous call to DIHED is inconsistent
with this dataset. Refer to Appendix 1. |
||
DI136 | DIASS : INVALID NUMBER OF TRANSFORMATION MATRICES (NUMTRA) : (NUMTRA | Parameter NUMTRA must be in the range 0 to 12 for assembly sub-components. | ||
DI137
|
|
An assembly is built up from a collection of models/sub-assemblies with optional transformations, which have already been entered into the FEMVIEW database. The requested model/sub-assembly does not exist in the database | ||
DI138 |
|
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1. | ||
DI139 |
|
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1. | ||
DI141 |
|
See 'Restrictions' section in chapter 1. | ||
DI142 |
|
See 'Restrictions' section in chapter 1. | ||
DI143 |
DI??? : ID ABOVE 99999 NOT ALLOWED FOR 5 DIGIT TEXT FILE : (IDNUM) |
See 'Restrictions' section in chapter 1. |
DI144 |
|
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1. | |||
DI145 | DIBLH : BEAM LOAD DATA FOR LAST BEAM NOT COMPLETED |
A previous call to DIBLH indicated a certain number of loads
of each type for this beam element. Routines DIBL1 to DIBL4 have not been
called often enough, and more load data is expected. |
|||
DI146 | DIBL? : BEAM LOAD HEADER EXPECTED | A previous call to DIBLH indicated a certain number of loads of each type for this beam element. Routines DIBL1 to DIBL4 have been called too many times, and no more load data is expected. | |||
DI147 |
|
A previous call to DIBLH indicated a certain number of loads of each type for this beam element. One of the routines DIBL1 to DIBL4 has been called too many times. | |||
DI148 |
|
Beam loading data types must be entered in the following order: point loads, distributed loads, point bending moments, distributed bending moments. | |||
DI149 | DIBL3 : DISTRIBUTED LOADS MUST PRECEDE POINT MOMENTS | Beam loading data types must be entered in the following order: point loads, distributed loads, point bending moments, distributed bending moments. | |||
DI151 |
|
Beam loading data types must be entered in the following order: point loads, distributed loads, point bending moments, distributed bending moments. | |||
DI152 |
|
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1. | |||
DI153 | DICON : CONSTRAINTS NOT ENTERED IN ASCENDING NODE ORDER | ||||
DI154 |
|
||||
DI155 | DIMPH : INVALID NUMBER(S) OF MPC NODES | Either MASTER or NSLAVE is not in the range 0-99999. | |||
DI156 |
|
The value of KEY set in a previous call to DIHED is inconsistent with this data set. Refer to Appendix 1. | |||
DI157
|
|
Routine DIRHA is called only once for each user-defined results dataset. | |||
DI158 |
|
The number of repeats specified in a previous call to DIE?H has not been followed by enough calls to DIE?R. See flow chart. | |||
DI159 |
|
The number of repeats specified in a previous call to DIE?H has been followed by too many calls to DIE?R. See flow chart. | |||
DI161 | DIRHB : ATTRIBUTE HEADER EXPECTED |
Routine DIRHA must be called before routine DIRHB. See flow
chart. |
|||
DI162 | DIRHB : NO MORE COMPONENT DEFINITIONS EXPECTED | The number of components specified in a previous call to DIRHA is inconsistent with the number of components that are now being entered via DIRHB. | |||
DI163 | DIRHC : COMPONENT DEFINITIONS NOT COMPLETED | The number of components specified in a previous call to DIRHA has not been with the number of components that are now being entered via DIRHC. | |||
DI164 | DIRHC : NO MORE ATTRIBUTE VARIANTS EXPECTED | The number of attribute variants specified in a previous call to DIRHA is inconsistent with the number of attribute variants that are now being entered via DIRHC. | |||
DI165 | DI??? : RESULTS HEADERS HAVE NOT BEEN COMPLETED | Routines DIRHA, DIRHB, and DIRHC have not been called correctly prior to entering a user-defined results dataset. | |||
DI166 | DI??? : CANNOT ENTER RESULTS, CURRENT RESULTS TYPE IS: (IRTYPE ) | The value of IRTYPE set in a previous call to DIRHA is inconsistent with this results data set type. Refer to Appendix 1. | |||
DI167 |
|
The number of components specified in a previous call to DIRHA has been followed by an inconsistent number of calls to DI??R. See flow chart. | |||
DI168 |
|
NTOTAL = NSLAVE + NMASTR and it must not exceed 30. | |||
DI169 | DI??? : ID NUMBERS NOT IN ASCENDING ORDER | Many nodal datasets require the data to be entered in ascending ID number. |
DI171 |
|
The maximum length is five. | ||
DI172 |
|
The number of repeats specified in a previous call to DINDH has been followed by too few calls to DINDR. See flow chart. | ||
DI173 | DINDR : NO MORE REPEATS EXPECTED FOR THIS NODE |
The number of repeats specified in a previous call to DINDH
has been followed by too many calls to DINDR. See flow chart. |
||
DI174
|
|
A previous call to DIMPH indicated that DIMPD should be called a certain number of times. DIMPH has been called for the next MPC without finishing entering data from the last one. | ||
DI175 | DIMPD : NO MORE REPEATS EXPECTED FOR THIS MPC | A previous call to DIMPH indicated that DIMPD should be called a certain number of times. DIMPD has been called too often. | ||
DI176 | DICON : IDOF AND IEDOF CANNOT BOTH BE ZERO | |||
DI177 |
|
See 'Restrictions' section in chapter 1. | ||
DI178 | DIMPD : PARAMETER NNODES MUST BE ZERO FOR MPC TYPE > 11: (NNODES ) | |||
DI179 | DIMPD : INCONSISTENT NUMBER OF MPC NODES FOR MPC <= 11: (NNODES ) | |||
DI181 |
|
Routine DILIM has probably been called when more results or data were expected from one of the datasets. When parallel processing, check that you are trying to process the correct dataset. | ||
DI182 |
|
Parameter IRTYPE must be in the range 1 to 5. | ||
DI183 |
|
Parameter NCOMPS must be in the range 1 to 20. |
DI184 |
|
Parameter NUMVAR must be in the range 0 to 5. | ||
DI185 |
|
Parameter INMENU must be 1 or 0. | ||
DI186 |
|
Parameter CTYPE must be 1,2,3,4,5,11,12,13, or 14. | ||
DI187 |
|
Value of INDEX1 is inconsistent with parameter CTYPE. | ||
DI188 | DIRHB : INVALID MATRIX COLUMN (INDEX2) | Value of INDEX1 is inconsistent with parameter CTYPE. | ||
DI189 |
|
Parameter IEXIST must be 1 or 0. |
||
DI191 |
|
See Appendix two for a list of valid FEMVIEW post calculation types. | ||
DI192 |
|
Parameter NVCOMP must be in the range 1 to 20 |
||
DI193 | DIHED : CANNOT ENTER RESULTS, NO MODEL ACTIVE |
A previous call to DIHED to enter a model name has probably
failed. |
||
DI194 |
|
A previous call to DIHED indicated that a certain dataset was to follow and it was not the one you are trying to use now. When parallel processing check the unit numbers. | ||
DI195 |
DICON : CANNOT ENTER NODAL CONSTRAINTS, CURRENT DATASET IS
: (KEY ) |
A previous call to DIHED indicated that a certain dataset was to follow and it was not nodal constraints. When parallel processing check the unit numbers. | ||
DI196 |
DICON : INVALID NODAL CONSTRAINT DEFINITION (IDOF) : (IDOF ) |
IDOF does not obey the rules defined for DICON. |
||
DI197 | DICON : INVALID NODAL CONSTRAINT DEFINITION (IEDOF): (IEDOF ) | IEDOF does not obey the rules defined for DICON. | ||
DI198 |
|
For datasets with header records an attempt has been made to enter data via DI??D or DI??R without first making a call to DI??H. | ||
DI199 |
|
Note that material ID numbers equal to zero may be used for multi-surface material independent data, but in general zero ID numbers for other data are invalid. |