3.15 DIEGR


Calling sequence : CALL DIEGR (IDGNUM, X, Y, Z, RESULT, NUMRES, IEXIT, IUNT)

Purpose : To enter element at Gauss points results.

Parameters :

  In
  IDGNUM Gauss point identification number (Integer)
  X,Y,Z   Gauss point co-ordinates (Real)
  RESULT Result components (Real array)
  NUMRES Number of result components in RESULT (Integer)
  IUNT   Temporary file channel number (Integer)
  Out
  IEXIT   Error condition

Use : This routine is called to enter all of the result components for an element at a particular Gauss point for a particular surface. It is called repeatedly to enter the results for each Gauss point at each surface. The number of Gauss points serves as the inner repeat, and the number of surfaces as the outer repeat. This routine must be preceded by routine DIEGH.

Errors : The error condition is indicated by the value of IEXIT.

IEXIT Meaning

0   Successful call
32   Current error must be cleared up first
129   Error in writing to temporary file on unit (iunt)
141   Id numbers cannot be less than 1
142   Id numbers above 999999 are invalid
143   Id above 99999 not allowed for character file
159   No more repeats expected for this element
167   This number of components not expected (numres)
198   Cannot enter data, entity header not entered
211   Invalid temporary file unit number (iunt)



[Next] [Up] [Back] [Previous] [Contents]