3.38 DINXH


Calling sequence : CALL DINXH (IDNNUM, NMATS, NSURFS, IEXIT, IUNT)

Purpose : To enter a materially dependent nodal local axis system for a node.

Parameters :

  In
  IDNNUM Node identification number (Integer)
  NMATS Number of materials for which local systems are to be entered (Int)
  NSURFS Number of surfaces for which local systems are to be entered (Int)
  IUNT   Temporary file channel number (Integer)
  Out
  IEXIT   Error condition

Use : This routine is used to enter a materially dependent nodal local axis header record. For each node; routine DINXH is called once only, and routine DINXD is called once for each material at each surface. The number of materials is the inner repeat, and the number of surfaces is the outer repeat when calling routine DINDR.

It is not necessary to enter local axis systems for every node.

Nodal local axis systems must be entered in the same order as the nodal co-ordinates data

was entered.

Errors : The error condition is indicated by the value of IEXIT.

IEXIT Meaning

0   Successful call
32   Current error must be cleared up first
129   Error in writing to temporary file on unit (iunt)
141   Id numbers cannot be less than 1
143   Id above 99999 not allowed for 5 digit character file
169   Id numbers not in ascending order
172   More repeats expected for previous node
194   Cannot enter this data type, current dataset is : (KEY )
211   Invalid temporary file unit number (iunt)



[Next] [Up] [Back] [Previous] [Contents]