3.22 DIGPH


Calling sequence : CALL DIGPH (IDENUM, ITYPE, IGROUP, NGAUSS, NSURFS, IEXIT, IUNT)

Purpose : To enter a Gauss point co-ordinates header record for a single element

Parameters :

  In
  IDENUM Element identification number (Integer)
  ITYPE   Femview element type number (integer)
  IGROUP Element group number (Integer)
  NGAUSS Number of points for which co-ordinates are to be entered (Integer)
  NSURFS Number of surfaces for which co-ordinates are to be entered (Int)
  IUNT   Temporary file channel number (Integer)
  Out
  IEXIT   Error condition

Use : This routine is used to enter a Gauss point co-ordinate header record. For each element; routine DIGPH is called once only, and routine DIGPD is called once for each Gauss point at each surface. The number of Gauss points is the inner repeat, and the number of surfaces is the outer repeat when calling routine DIGPD.

It is not necessary to enter Gauss point co-ordinates for every element.

Gauss point co-ordinates must be entered in the same order as the element topology data was entered.

Errors : The error condition is indicated by the value of IEXIT.

IEXIT   Meaning

0     Successful Call
32     Current error must be cleared up first
129     Error in writing to temporary file on unit (iunt)
141     Id numbers cannot be less than 1
143     Id above 99999 not allowed for 5 digit character file
158     More repeats expected for previous element
194     Cannot enter this data type, current dataset is : (KEY )
211     Invalid temporary file unit number (iunt)



[Next] [Up] [Back] [Previous] [Contents]